Bm-1053, Bm-1054, Bm-1055 – Dell POWEREDGE M1000E User Manual
Page 156: Bm-1056

80
Fabric OS Message Reference
53-1001767-01
BM-1053
10
Severity
INFO
BM-1053
Message
establish connection between CP and Application Processor. Faulting switch.
Probable Cause
Indicates the control processor (CP) could not establish a connection with the application
processor to communicate.
Recommended
Action
On the Brocade 7500 or 7600, switch off and switch on all the primary power to power-cycle the
unit.
Severity
WARNING
BM-1054
Message
Auto-leveling AP firmware to match system firmware.
Probable Cause
Indicates the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:
•
Blade firmware was detected to be different from control processor (CP) firmware due to a
firmware upgrade.
•
The blade was just inserted and had a different version of the firmware loaded.
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
Severity
INFO
BM-1055
Message
Firmwaredownload timed-out for AP. Faulting switch.
Probable Cause
Indicates the firmwareDownload command on the application processor (AP) blade has failed.
Recommended
Action
Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
DCX, 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit.
Severity
WARNING
BM-1056
Message
configured. Persistently disabling all ports on the switch.