Fabric OS Message Reference
53-1001767-01
FCR-1005
34
Recommended
Action
Verify that the devices were intended to be taken offline. If not, verify that the devices are
functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check
for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary.
Severity
INFO
FCR-1005
Message
zone device removed at port
Probable Cause
Indicates that a device is removed from the logical storage area network (LSAN) zone in the edge
fabric.
Recommended
Action
No action is required.
Severity
INFO
FCR-1006
Message
zone device added at port
Probable Cause
Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric.
Recommended
Action
No action is required.
Severity
INFO
FCR-1007
Message
zone deleted at port
Probable Cause
Indicates that a logical storage area network (LSAN) zone attached to the specified port was
deleted from the edge fabric.
Recommended
Action
No action is required.
Severity
INFO
FCR-1008
Message
zone created at port