Bl-1023, Bl-1024, Bl-1025 – Dell POWEREDGE M1000E User Manual
Page 143: Bl-1026

Fabric OS Message Reference
67
53-1001767-01
BL-1023
7
Severity
CRITICAL
BL-1023
Message
slot
was reset before blade init completed. As a result the blade
is faulted.
Probable Cause
Indicates that the blade was reset before the initialization completed.
Recommended
Action
Restart or power cycle the blade.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1024
Message
blade in slot
will be reset as part of the firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.
Severity
INFO
BL-1025
Message
Virtualization ports on the blade in slot
will be reset as part of
the firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization
data elements or FC Fastwrite ports were reset.
Recommended
Action
No action is required.
Severity
INFO
BL-1026
Message
port offline during warm recovery, state