Cvlc-1008, Cvlc-1009, Cvlc-1010 – Dell POWEREDGE M1000E User Manual
Page 201

Fabric OS Message Reference
125
53-1001767-01
CVLC-1008
19
Recommended
Action
If you want to preserve the user data, use cryptocfg --modLUNpolicy -cleartext to convert to clear
text LUN.
Use cryptocfg ---modLUNpolicy -disable_allowdecrypt to disable decryption of existing data. Then try
the LUN deletion again.
Severity
ERROR
CVLC-1008
Message
failure:
Probable Cause
Indicates that LUN discovery failed.
Recommended
Action
No action is required.
Severity
ERROR
CVLC-1009
Message
type: should be (Disk/Tape)>.\nContainer: WWN>, LUN ID: Probable Cause Indicates that LUN discovery failed. Recommended Action No action is required. Severity ERROR CVLC-1010 Message is required for tape container: Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Action Obtain license for non-Brocade mode. Severity ERROR