beautypg.com

Cvlc-1008, Cvlc-1009, Cvlc-1010 – Dell POWEREDGE M1000E User Manual

Page 201

background image

Fabric OS Message Reference

125

53-1001767-01

CVLC-1008

19

Recommended

Action

If you want to preserve the user data, use cryptocfg --modLUNpolicy -cleartext to convert to clear
text LUN.

Use cryptocfg ---modLUNpolicy -disable_allowdecrypt to disable decryption of existing data. Then try
the LUN deletion again.

Severity

ERROR

CVLC-1008

Message

, [CVLC-1008], ,, ERROR, , LUN discovery

failure: , Container: , Initiator:

, LUN ID: .

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.

Severity

ERROR

CVLC-1009

Message

, [CVLC-1009], ,, ERROR, , Wrong device

type: should be , found

(Disk/Tape)>.\nContainer: , Initiator:

WWN>, LUN ID: .

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.

Severity

ERROR

CVLC-1010

Message

, [CVLC-1010], ,, ERROR, , Tape license

is required for tape container: .

Probable Cause

Indicates that the tape container is configured with non-Brocade mode but there is no valid license.

Recommended

Action

Obtain license for non-Brocade mode.

Severity

ERROR