SEC-1099
90
SEC-1099
Message
your switch before running secModeEnable.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
SEC-1100
Message
present. Command terminated.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
SEC-1101
Message
enable security on all switches. Please retry later.
Probable Cause
Indicates the security enable failed on the fabric because one or more switches in the fabric are
busy.
Recommended
Action
Verify that the security event was planned. If the security event was planned, run the
secFabricShow command to verify that all switches in the fabric are in the ready state. When all
switches are in the ready state, retry the operation.
Severity
ERROR
SEC-1102
Message
download