Sec-1167, Sec-1168, Sec-1170 – Dell POWEREDGE M1000E User Manual
Page 614

538
Fabric OS Message Reference
53-1001767-01
SEC-1167
90
SEC-1167
Message
failover is in process. Command terminated.
Probable Cause
Indicates that because another failover is already in progress, this failover attempt cannot proceed.
Recommended
Action
Verify the security event was planned. If the security event was planned, retry fabric configurations
server (FCS) failover after current failover has completed, if this switch should become primary
FCS. If the security event was not planned, take appropriate action as defined by your enterprise
security policy.
Severity
ERROR
SEC-1168
Message
failover is busy. Please retry later.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configurations server (FCS) is distributing the security database to
the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
SEC-1170
Message
must be executed on the Primary FCS switch, the first reachable switch in the FCS
list.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
INFO