Fabric OS Message Reference
47
53-1001767-01
AUTH-1031
4
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1031
Message
retrieve secret value: port
Probable Cause
Indicates that the secret value was not set properly for the authenticated entity.
Recommended
Action
Reset the secret value by using the secAuthSecret command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
Severity
ERROR
AUTH-1032
Message
generate for
code
Probable Cause
Indicates that the authentication process failed to generate specific data (that is, challenge, nonce,
or response data) for an authentication payload. This usually relates to internal failure.
A nonce is a single-use, usually random value used in authentication protocols to prevent replay
attacks.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1033
Message
Probable Cause
Indicates that an entity was not configured in the switch connection control (SCC) policy and tried
to connect to the port.