Spc-3005, Spc-3006 – Dell POWEREDGE M1000E User Manual
Page 652

576
Fabric OS Message Reference
53-1001767-01
SPC-3005
93
Probable Cause
Indicates the output wrapping KEK for the DEK to be created does not exist within the EE Crypto
Module.
Recommended
Action
For opaque key vaults such as RKM, recover the missing Master Key to current or alternate
position.
Severity
ERROR
SPC-3005
Message
containing Encryption Engine>, DEK: Probable Cause Indicates the cause depends on the SP status code: • 14 - Attempt to inject a DEK to an invalid FPGA table index • 14 - Invalid input DEK format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Action Contact technical support. Severity ERROR SPC-3006 Message containing Encryption Engine>, DEK: Probable Cause Indicates the cause depends on the SP status code: • 2 - Invalid input DEK format • 14 - Rewrapping not allowed: primary KEK generation is in progress • 31 - DEK could not be wrapped • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Action For status code 14, complete primary KEK generation; otherwise, contact technical support. Severity ERROR