Icpd system messages, Chapter 52, Icpd-1001 – Dell POWEREDGE M1000E User Manual
Page 473: Icpd-1002, Icpd-1003, Icpd-1004, Chapter

Fabric OS Message Reference
397
53-1001767-01
Chapter
52
ICPD System Messages
ICPD-1001
Message
allocate memory: (
Probable Cause
Indicates that the specified function failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command.
Reboot or power cycle the switch.
Severity
ERROR
ICPD-1002
Message
initialize
Probable Cause
Indicates that an initialization of a module within the ICPD failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference for more information on this command.
Severity
ERROR
ICPD-1003
Message
configuration has been committed by switch (
Probable Cause
Indicates the iSCSI configuration has been committed by a remote switch in the fabric.
Recommended
Action
No action is required.
Severity
INFO
ICPD-1004
Message
service is detected on multiple switches in fabric.
Probable Cause