Zone-1007, Zone-1008, Zone-1010 – Dell POWEREDGE M1000E User Manual
Page 735: Zone-1012

Fabric OS Message Reference
659
53-1001767-01
ZONE-1007
111
ZONE-1007
Message
Ioctl(
(
Probable Cause
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from
which the failure is reported is listed as part of the error message. This is usually a programming
error when adding content-addressable memory (CAM) entries before the filter setup.
Recommended
Action
There are two ways to avoid this problem.
•
Avoid having too many hosts zoned with a set of target devices at a single port.
•
Avoid having too many zones directed at a single port group on the switch.
Severity
INFO
ZONE-1008
Message
port
Probable Cause
Indicates the total number of entries of S_ID CAM is above the limit while creating or adding a zone
group. The maximum number of content-addressable memory (CAM) entries allowed depends on
the application-specific integrated circuit (ASIC).
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
port.
Severity
WARNING
ZONE-1010
Message
Duplicate entries in zone(
Probable Cause
Indicates there are duplicate entries in a zone object. A zone object member is specified twice in a
given zone object. This message occurs only when enabling a zone configuration.
Recommended
Action
Check the members of the zone and delete the duplicate member.
Severity
WARNING
ZONE-1012
Message
All ports are offline.
Probable Cause
Indicates that all the ports in a zone are offline.