FCR-1024
34
FCR-1024
Message
zone
device entries for edge LSAN exhausted.
Probable Cause
Indicates that the number of devices in a logical storage area network (LSAN) defined in the edge
fabric exceeds the local LSAN zone database limitations.
Recommended
Action
Remove excess device entries from this LSAN zone until the number of devices is within the range
of the local LSAN zone database limitations.
Severity
WARNING
FCR-1025
Message
phantom node WWN entries exhausted.
Probable Cause
Indicates that the number of node world wide names (WWNs) detected to be in use exceeds the
local node WWN resources.
Recommended
Action
Reduce the number of node WWNs required by limiting the remote edge fabric connectivity (which
limits the number of translate domains).
Severity
WARNING
FCR-1026
Message
number> Node WWN roll over. Probable Cause Indicates that the node world wide name (WWN) pool has rolled over in the specified slot, and Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed To avoid WWN conflicts, all EX_Ports attached to fabrics with highly dynamic changes to EX_Port Severity INFO FCR-1027 Message number> port WWN roll over.
WWN entries detected to not be in use are reused as needed.
in a very large MetaSAN environment with large number of logical storage area network (LSAN)
devices and fabrics, or there are highly dynamic changes to EX_Port connectivity. WWN conflicts
might cause unpredictable behavior in management applications.
connectivity should be disabled and then re-enabled.