Bl-1034, Bl-1035, Bl-1036 – Dell POWEREDGE M1000E User Manual
Page 146

70
Fabric OS Message Reference
53-1001767-01
BL-1034
7
Probable Cause
Indicates that the system has timed out while waiting for disable messages from the user ports
after disabling the ports.
Recommended
Action
Restart or power cycle the blade. Run the systemVerification command to verify that the blade does
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.
Refer to the Fabric OS Command Reference for more information on the systemVerification
command.
Severity
CRITICAL
BL-1034
Message
number> FC Initialization completed. Probable Cause Indicates that the slot has completed initializing Fibre Channel (FC) ports. Recommended Action No action is required. Severity INFO BL-1035 Message number> iSCSI port Probable Cause Indicates that the slot has completed initializing the specified iSCSI port. Recommended Action No action is required. Severity INFO BL-1036 Message blade in slot = be disabled in order to enable the 8G blade in the chassis. Probable Cause Indicates that the FOS 6.0, 8G blade with legacy mode (EX_port having stag) will be disabled. Recommended Action Disable all EX/VEX ports and perform a slotpoweroff or slotpoweron operation on the 8G blade. Severity CRITICAL
Also, all EX/VEX ports can be re-enabled now.