SWCH-1011

98

Severity

WARNING

SWCH-1011

Message

, [SWCH-1011], ,, WARNING, , HA state

out of sync: Standby CP (ver = ) does not support Trunk Area

functionality. (active ver = , Trunk Area enabled on switch =

<'1' if Trunk Area ports exist; Otherwise '0'>).

Probable Cause

Indicates the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.

Recommended

Action

Load a firmware version on standby that supports Trunk Area functionality, using the
firmwareDownload command.

Severity

WARNING

SWCH-1012

Message

, [SWCH-1012], ,, INFO, , Trunk Area

() has been enabled for one or more ports).

Probable Cause

Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has
been updated.

Recommended

Action

No action is required.

Severity

INFO

SWCH-1013

Message

, [SWCH-1013], ,, INFO, , Trunk Area has

been disabled for one or more ports.

Probable Cause

Indicates that a Trunk Area assignment has been disabled for one or more ports and the
configuration file has been updated.

Recommended

Action

No action is required.

Severity

INFO

SWCH-1014

Message

, [SWCH-1014], ,, INFO, , All Trunk

Areas have been disabled.

Probable Cause

Indicates that all Trunk Areas have been disabled and the configuration file has been updated.