Ag-1004, Ag-1005, Ag-1006 – Dell POWEREDGE M1000E User Manual
Page 102: Ag-1007

26
Fabric OS Message Reference
53-1001767-01
AG-1004
2
Severity
WARNING
AG-1004
Message
response to fabric login (FLOGI) request from the fabric for N_Port
Probable Cause
Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.
Recommended
Action
Check the configuration of the fabric switch.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AG-1005
Message
response was dropped because F_Port
Probable Cause
Indicates the F_Port connected to the host is offline, which caused the FDISC response to drop.
Recommended
Action
Check the configuration of the host connected to the specified F_Port.
Severity
WARNING
AG-1006
Message
mode has been
Probable Cause
Indicates Access Gateway mode has been enabled or disabled.
Recommended
Action
Run the ag --modeshow command to verify the current status of the Access Gateway mode.
Severity
INFO
AG-1007
Message
response not received for the N_Port
connected to the fabric.
Probable Cause
Indicates the N_Port connected to the fabric switch is not online. The specified N_Port has been
disabled.