beautypg.com

Ag-1022, Ag-1023, Ag-1024 – Dell POWEREDGE M1000E User Manual

Page 107: Ag-1025

background image

Fabric OS Message Reference

31

53-1001767-01

AG-1022

2

AG-1022

Message

, [AG-1022], ,, INFO, , F_Port

is failed over to its preferred N_Port .

Probable Cause

Indicates the specified F_Port is failing over to its preferred N_Port.

Recommended

Action

Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.

Severity

INFO

AG-1023

Message

, [AG-1023], ,, INFO, , F_Port

mapped to offline N_Port is failed over to its preferred N_Port .

Probable Cause

Indicates the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its
preferred set and is online.

Recommended

Action

Run the ag --mapshow command to display updated F_Port -to -N_Port mapping.

Severity

INFO

AG-1024

Message

, [AG-1024], ,, INFO, , F_Port

is failed back to its preferred N_Port .

Probable Cause

Indicates the specified N_Port is failing back F_Ports, which are failed over to some other N_Port.

Recommended

Action

Run the ag --mapShow command to display the updated F_Port-to-N_Port mapping.

Severity

INFO

AG-1025

Message

, [AG-1025], ,, ERROR, , Port group of

Slave N_Port is different than its Master N_Port .

Probable Cause

Indicates that the port groups of the Master and Slave N_Ports are different while the Trunk Area
assigned to the attached F_Ports on the edge switch is the same.

Recommended

Action

Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is
assigned to all ports in the system and run the porttrunkarea --enable command to reconfigure the
Trunk Area.

Severity

ERROR