Hil-1309, Hil-1310, Hil-1311 – Dell POWEREDGE M1000E User Manual
Page 452: Hil-1401

376
Fabric OS Message Reference
53-1001767-01
HIL-1309
45
Recommended
Action
Replace the faulty fan field-replaceable units (FRUs) immediately.
Severity
ERROR
HIL-1309
Message
fan
FRUs failed. Replace failed fan FRUs immediately.
Probable Cause
Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Replace the faulty fan field-replaceable unit (FRU)s immediately.
Severity
ERROR
HIL-1310
Message
fans faulty.
Probable Cause
Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Since the fans are not field replaceable, replace the switch if the temperature is high.
Severity
WARNING
HIL-1311
Message
faulty.
Probable Cause
Indicates recovery from earlier condition of one or more fans having failed.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of
faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity
INFO
HIL-1401
Message
missing. Install fan FRU immediately.