FW-1042
42
Probable Cause
Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed. The
transmit performance area measures the amount of outgoing laser to help you determine if the
SFP is in good working condition or not. If the counter often exceeds the threshold, the SFP is
deteriorating.
Recommended
Action
Transmitting laser fluctuations usually indicate a deteriorating SFP. If this message occurs
repeatedly, replace the SFP.
Severity
INFO
FW-1042
Message
below low boundary(High=
Probable Cause
Indicates that the transmit power value of the small form-factor pluggable (SFP) has fallen below
the low boundary. The transmit performance area measures the amount of outgoing laser to help
you determine if the SFP is in good working condition or not. If the counter often exceeds the
threshold, the SFP is deteriorating.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables
or SFPs. Check for damage from heat or age.
Severity
WARNING
FW-1043
Message
above high boundary(High=
Probable Cause
Indicates that the transmit power value of the small form-factor pluggable (SFP) has risen above
the high boundary. The transmit performance area measures the amount of outgoing laser to help
you determine if the SFP is in good working condition or not. If the counter often exceeds the
threshold, the SFP is deteriorating.
Recommended
Action
Replace the SFP.
Severity
WARNING
FW-1044
Message
between high and low boundaries(High=
is