beautypg.com

Zone-1030, Zone-1031, Zone-1032 – Dell POWEREDGE M1000E User Manual

Page 740: Zone-1033

background image

664

Fabric OS Message Reference

53-1001767-01

ZONE-1030

111

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

WARNING

ZONE-1030

Message

, [ZONE-1030], ,, WARNING, , Converting

the zone db for PID format change failed.

Probable Cause

Indicates the current zone database could not be converted to reflect the PID format change. Most
likely this is caused by the size of the zone database.

Recommended

Action

Change the PID format back to its original format. Reduce the size of the zone database. Then you
can change the PID format to the requested format.

Severity

WARNING

ZONE-1031

Message

, [ZONE-1031], ,, ERROR, , Switch is in

interop mode. (switch, port) members not supported.

Probable Cause

Indicates the switch is set to interop mode using the interopMode command. Interop mode does
not allow members in the active zone database.

Recommended

Action

Remove all members from the zone database, or convert them to world wide
name (WWN) zoning.

Severity

ERROR

ZONE-1032

Message

, [ZONE-1032], ,, ERROR, , Domain

Max Zone DB size .

Probable Cause

Indicates the specified domain does not have enough memory for the zone database being
committed.

Recommended

Action

Reduce the size of the zone database and retry the operation.

Severity

ERROR

ZONE-1033

Message

, [ZONE-1033], ,, ERROR, , Domain

Lowest Max Zone DB size.