FCR-1056
34
Severity
INFO
FCR-1056
Message
WWN> with front domain ID Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN. Recommended Action No action is required if backbone-to-edge routing is not needed. Otherwise replace the switch with Severity INFO FCR-1057 Message number> ) incompatible long distance parameters on link. Probable Cause Indicates that the port, which is configured in long distance mode, has incompatible long distance Recommended Action Check the port configuration on both sides of the link using the portCfgShow command. Investigate the other switch for more details. Run the errShow command on the other switch to Severity ERROR FCR-1058 Message number> isolated due to mismatched configuration parameter; reason>. Probable Cause Indicates that the specified port was isolated after segmentation caused by mismatched Recommended Action Check the switches on both ends of the link for a possible mismatch in switch or port configuration Run the portCfgExport command to modify the appropriate parameters on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote Severity WARNING
one that supports backbone to edge routing.
parameters.
view the error log for additional messages.
configuration parameters or by domain ID assigned by the principal switch that did not match the
insistent domain ID of this port.
parameters such as Operating Mode, E_D_TOV, R_A_TOV, Domain ID Offset, etc.
switch.