Fabric OS Message Reference
87
53-1001767-01
Chapter
12
CDR System Messages
CDR-1001
Message
number> port fault. Please change the SFP or check cable Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable Recommended Action Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have deteriorated or the Fibre Channel cable is faulty. Replace the SFPs or Severity ERROR CDR-1002 Message chip faulted due to internal error. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover Severity ERROR CDR-1003 Message number>, Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may Recommended Action Whenever this error occurs, restart the system at the next maintenance window. If the problem
between peer ports, or that the port speed configuration does not match the capability of the SFP.
cable, if necessary.
the system. For a non-bladed system, perform fastBoot command on the switch to recover the
system.
degrade data traffic.
persists, replace the blade.