Sulb-1036, Sulb-1037, Sulb-1038 – Dell POWEREDGE M1000E User Manual
Page 696

620
Fabric OS Message Reference
53-1001767-01
SULB-1036
97
Probable Cause
Indicates an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.
Recommended
Action
Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
contact your switch service provider.
Severity
ERROR
SULB-1036
Message
being logged> Probable Cause Indicates the firmware version is running in the system. This is generally logged before download Recommended Action No action is required. Severity INFO SULB-1037 Message failed. Reboot the switch manually using the reboot command. However, it will disrupt the FC traffic. Probable Cause Indicates HCL has failed. Many reasons, such as domain not confirmed, can cause this failure. Recommended Action Run the reboot command to reboot the switch manually. Severity INFO SULB-1038 Message Skip the firmwaredownload command on the co-CPU. Probable Cause Indicates that the Main CPU cannot access the co-CPU to update the firmware on the co-CPU or run Recommended Action After firmwaredownload completes, reboot the CP manually to bring up the co-CPU and run the Severity WARNING
and after download of the firmware to store version information.
any other firmwaredownload command on the co-CPU. If firmwareDownload in progress it will
continue without updating the co-CPU firmware.
firmwareDownload command again. If the problem persists, contact the service provider.