Bl-1037, Bl-1038, Bl-1039 – Dell POWEREDGE M1000E User Manual
Page 147: Bl-1041

Fabric OS Message Reference
71
53-1001767-01
BL-1037
7
BL-1037
Message
chip in slot =
BE/BI port fault.
Probable Cause
Indicates a fault on the chip and that all ports on the chip have been disabled.
Recommended
Action
No action is required.
Severity
CRITICAL
BL-1038
Message
FPGA image version detected, please restart the switch for recovery.
Probable Cause
Indicates that the FPGA image version is incompatible with the software version.
Recommended
Action
Restart the switch. If the message persists, replace the switch.
Severity
CRITICAL
BL-1039
Message
FPGA image version detected, faulting the blade in slot
Probable Cause
Indicates that the FPGA image version is incompatible with the software version.
Recommended
Action
Power cycle the blade. If the message persists, replace the blade.
Severity
CRITICAL
BL-1041
Message
mode is enabled on default switch, Faulting the blade w/ ID that has the mini SFP+ that does not support it> in slot not support this mode. Probable Cause Indicates that the blade does not support dynamic area mode on default switch. Recommended Action Turn off the dynamic area mode through Configure CLI. Severity CRITICAL