Fabric OS Message Reference
53-1001767-01
EM-1070
22
EM-1070
Message
number> is being powered on. Probable Cause Indicates a blade is being intentionally powered on. Recommended Action No action is required. Severity INFO EM-2003 Message Switch for pizza boxes> has failed the POST tests. FRU is being faulted. Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the Recommended Action On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The ID will be Switch for non-bladed systems.
problems. To run this command root access is required. Refer to theFabric OS Reference
Manual for more information on this command.