Ssmd-1217, Ssmd-1300, Ssmd-1301 – Dell POWEREDGE M1000E User Manual
Page 679: Ssmd-1302

Fabric OS Message Reference
603
53-1001767-01
SSMD-1217
96
SSMD-1217
Message
could not comply with FCoE scheduler policy for CEE Map
Probable Cause
Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE
configuration into an ETS scheduler policy implementable by the dataplane ASIC.
Recommended
Action
Redefine CEE Map and FCoE into a configuration that translates into into an ETS scheduler policy
requiring 8 or fewer Traffic Class.
Severity
WARNING
SSMD-1300
Message
Probable Cause
Indicates that a CEEMap is created.
Recommended
Action
No action is required.
Severity
INFO
SSMD-1301
Message
Probable Cause
Indicates that a CEEMap is deleted.
Recommended
Action
No action is required.
Severity
INFO
SSMD-1302
Message
Probable Cause
Indicates that PGs added to or removed from existing ceemap.
Recommended
Action
No action is required.
Severity
INFO