88

Fabric OS Message Reference

53-1001767-01

CDR-1004

12

Severity

CRITICAL

CDR-1004

Message

, [CDR-1004], , FFDC, ERROR, ,

number>, : invalid DMA ch pointer, chan:,

good_addr:0x, bad_addr:0x.

Probable Cause

Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.

Recommended

Action

Whenever this error occurs, restart the system at the next maintenance window. If the problem
persists, replace the blade.

Severity

ERROR

CDR-1005

Message

, [CDR-1005], ,, WARNING, ,

number>, : at next port state change, best effort

QOS will be turned off automatically due to best effort is no longer supported

under this configuration.

Probable Cause

Indicates QoS will be turned off automatically at the next port state change because best effort is
no longer supported on a 4G platform or 8G platform long distance port.

Recommended

Action

No action is required.

Severity

WARNING

CDR-1006

Message

, [CDR-1006], ,, WARNING, ,

number>, : QOS overwrites portcfglongdistance

vc_translation_link_init. ARB will be used on the link.

Probable Cause

Indicates QoS overwrites the portcfglongdistance vc_translation_link_init 0 choice. ARB will be
used on the link.

Recommended

Action

No action is required.

Severity