Fw-1048, Fw-1049, Fw-1050 – Dell POWEREDGE M1000E User Manual
Page 370: Fw-1051

294
Fabric OS Message Reference
53-1001767-01
FW-1048
42
Severity
WARNING
FW-1048
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1049
Message
has changed(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed.
Recommended
Action
Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP.
Severity
INFO
FW-1050
Message
below low boundary(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity
WARNING
FW-1051
Message
above high boundary(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures.