beautypg.com

Fw-1048, Fw-1049, Fw-1050 – Dell POWEREDGE M1000E User Manual

Page 370: Fw-1051

background image

294

Fabric OS Message Reference

53-1001767-01

FW-1048

42

Severity

WARNING

FW-1048

Message

, [FW-1048], ,, INFO, ,

between high and low boundaries(High=, Low=). Current value

is .

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1049

Message

, [FW-1049], ,, INFO, ,

has changed(High=, Low=). Current value is .

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed.

Recommended

Action

Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP.

Severity

INFO

FW-1050

Message

, [FW-1050], ,, WARNING, ,

below low boundary(High=, Low=). Current value is

.

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.

Recommended

Action

Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.

Severity

WARNING

FW-1051

Message

, [FW-1051], ,, WARNING, ,

above high boundary(High=, Low=). Current value is

.

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures.