9
Probable Cause
Indicates that an IPsec or IKE policy was deleted and the configuration file was updated.
Recommended
Action
No action is required.
Severity
INFO
BLS-1004
Message
Pipelining is being disabled slot configured tunnel ID (0-7)>. Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support the Tape Read Recommended Action No action is required. Severity INFO BLS-1005 Message number>,P port faulted due to SFP validation failure. Please check if the SFP is valid for the configuration. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Action Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have Severity ERROR
Pipelining feature.
deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable, if necessary.