beautypg.com

Bls-1004, Bls-1005 – Dell POWEREDGE M1000E User Manual

Page 152

background image

76

Fabric OS Message Reference

53-1001767-01

BLS-1004

9

Probable Cause

Indicates that an IPsec or IKE policy was deleted and the configuration file was updated.

Recommended

Action

No action is required.

Severity

INFO

BLS-1004

Message

, [BLS-1004], ,, INFO, , Tape Read

Pipelining is being disabled slot port tunnel

configured tunnel ID (0-7)>.

Probable Cause

Indicates that the FOS version on the remote end of the tunnel does not support the Tape Read
Pipelining feature.

Recommended

Action

No action is required.

Severity

INFO

BLS-1005

Message

, [BLS-1005], ,, ERROR, , S

number>,P [OID 0x8x]: :

port faulted due to SFP validation failure. Please check if the SFP is valid for

the configuration.

Probable Cause

Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports.

Recommended

Action

Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have
deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable, if necessary.

Severity

ERROR