Fcpd system messages, Chapter 32, Fcpd-1001 – Dell POWEREDGE M1000E User Manual
Page 287: Fcpd-1002, Fcpd-1003, Chapter

Fabric OS Message Reference
211
53-1001767-01
Chapter
32
FCPD System Messages
FCPD-1001
Message
failed on
.
Probable Cause
Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing
failed on the L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
The error string can be either of the following:
•
L_Port port_number ALPA alpa_number
•
F_Port port_number
Recommended
Action
This can happen when the firmware on the device controller on the specified port has a defect.
Check with the device vendor for a firmware upgrade containing a defect fix.
Severity
WARNING
FCPD-1002
Message
number>, bad R_CTL for fcp probing: 0x Probable Cause Indicates that the response frame received on the specified port for an inquiry request contains an Recommended Action This can happen only if the firmware on the device controller on the specified port has a defect. Severity WARNING FCPD-1003 Message on which is possibly a private device which is not supported in this port type Probable Cause Indicates that private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade DCX, 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices. Severity INFO
invalid value in the routing control field.
Check with the device vendor for a firmware upgrade containing a defect fix.
Refer to the switch vendor for a list of other port types that support private devices for inclusion into
the fabric.