Fabric OS Message Reference
53-1001767-01
SWCH-1019
98
SWCH-1019
Message
name of device> tries to flogi, reject FLOGI as persistent PID is set on device and port Probable Cause Indicates a WWN-PID and PortAddress binding collision. Recommended Action The Peristent PID is set on the device and requested area cannot be assigned because it is user Severity INFO SWCH-1020 Message of sync: Standby CP (ver = AG(Active CP version = Probable Cause Indicates the standby control processor (CP) does not support links to AG running QOS. Recommended Action Load a firmware version on the standby CP that supports QOS links to AG, using the Severity WARNING SWCH-1021 Message out of sync: Standby CP (ver = area on default switch (Active CP version = Probable Cause Indicates the standby control processor (CP) does not support dynamic area on default switch. Recommended Action Load a firmware version on the standby CP that supports dynamic area on default switch, using the Severity WARNING
bound to a different port. Remove the WWN-PID binding or remove portAddress binding and
re-enable the port and then run the wwnaddress --unbind wwn command or the portaddress
--unbind slot/port command.
firmwareDownload command.
firmwareDownload command.