598
Fabric OS Message Reference
53-1001767-01
SSMD-1005
96
Probable Cause
Indicates that the specified function has failed to unlock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.
Severity
ERROR
SSMD-1005
Message
failed.
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected, severe error
during basic startup and initialization.
Recommended
Action
Restart or power cycle the switch .If the condition persists then download a new firmware version
using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for
more information on this command.
Severity
ERROR
SSMD-1200
Message
programming ASIC
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for the enforcing Multicast Rate Limit feature.
Recommended
Action
Delete and reapply QoS Multicast Rate Limit policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1201
Message
programming ASIC
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for the enforcing Multicast Tail Drop feature.
Recommended
Action
Delete and reapply QoS Multicast Tail Drop policy. Restart or power cycle the switch.