Ficn-1004, Ficn-1005, Ficn-1006 – Dell POWEREDGE M1000E User Manual
Page 316

240
Fabric OS Message Reference
53-1001767-01
FICN-1004
35
Severity
WARNING
FICN-1004
Message
Emulation License Key is not installed.
Probable Cause
Indicates FICON XRC Emulation requires a License Key.
Recommended
Action
Use the appropriate License Key.
Severity
WARNING
FICN-1005
Message
Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or
Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled or Disabled> TinTir
<1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON
Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 - FICON Write
Emulation Read Block ID Emulation Enabled or Disabled>.
Probable Cause
Indicates the configuration was changed manually.
Recommended
Action
No action is required.
Severity
INFO
FICN-1006
Message
GEPort < 0 or 1 - GE port number> TID
or 0 - FICON XRC Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write
Emulation Enabled or Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled
or Disabled> TinTir <1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck
<1 or 0 - FICON Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 -
FICON Write Emulation Read Block ID Emulation Enabled or Disabled>.
Probable Cause
Indicates the FCIP Tunnel ID associated with the FICON tunnel must be down or disabled for a
feature change to become effective.
Recommended
Action
Disable the applicable FCIP tunnel to make the feature change effective.
Severity
WARNING