Page 171: Chassis-1003, Chassis-1004, Chapter

Fabric OS Message Reference
95
53-1001767-01
Chapter
15
CHASSIS System Messages
CHASSIS-1002
Message
ki_gd_register_action failed with rc =
Probable Cause
Indicates an internal error.
Recommended
Action
For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the
blade to recover the system. For a non-bladed system, execute the fastBoot command on the
switch to recover the system.
Severity
ERROR
CHASSIS-1003
Message
ENABLED but Not Ready during recovery, disabling slot =
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR
CHASSIS-1004
Message
attach failed during recovery, disabling slot = value>. Probable Cause Indicates that a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn Severity ERROR
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.