Sulb-1035, Sulb-1037, Sulb-1038 – Dell POWEREDGE M1000E User Manual
Page 826

750
Fabric OS Message Reference
53-1001767-01
SULB-1035
128
Recommended
Action
Reboot the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.
Severity
ERROR
SULB-1035
Message
AUDIT,
Probable Cause
Indicates an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.
Recommended
Action
Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
contact your switch service provider.
Severity
ERROR
SULB-1037
Message
AUDIT,
manually using the reboot command. However, it will disrupt the FC traffic.
Probable Cause
Indicates HCL has failed. Many reasons, such as domain not confirmed, can cause this failure.
Recommended
Action
Run the reboot command to restart the switch manually.
Severity
ERROR
SULB-1038
Message
AUDIT,
properly. Skip the firmwaredownload command on the co-CPU.
Probable Cause
Indicates that the Main CPU cannot access the co-CPU to update the firmware on the co-CPU or run
any other firmwaredownload command on the co-CPU. If firmwareDownload in progress it will
continue without updating the co-CPU firmware.
Recommended
Action
After firmwaredownload completes, reboot the CP manually to bring up the co-CPU and run the
firmwareDownload command again. If the problem persists, contact the service provider.
Severity
WARNING