Sysc-1004, Sysc-1005 – Dell POWEREDGE M1000E User Manual
Page 706

630
Fabric OS Message Reference
53-1001767-01
SYSC-1004
99
It could also indicate that the current option number could not be read from the chassis option
storage device (the world wide name (WWN) card).
This message occurs only on the Brocade 24000 and 48000.
Recommended
Action
As indicated in the message, run the chassisConfig command to change to one that is valid on this
platform running this firmware. Note that the chassisConfig option 1 should be valid for all
platforms running any valid firmware.
Severity
CRITICAL
SYSC-1004
Message
restart successful
Probable Cause
Indicates that a terminated daemon is being restarted by the system automatically.
Recommended
Action
Use the supportSave command to gather troubleshooting data.
Severity
INFO
SYSC-1005
Message
Probable Cause
Indicates a terminated daemon has not restarted, either a restart limit has been reached or a
restart action has failed.
Recommended
Action
Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover
command to recover the system and limit the traffic disruption.
Severity
WARNING