Fabric OS Message Reference

53-1001767-01

AN-1004

3

AN-1004

Message

, [AN-1004], ,, WARNING, , Slot

number>, port is a congestion bottleneck.

percent of last

seconds were affected by this condition.

Probable Cause

Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.

Recommended

Action

Add more capacity on the path, using trunk links if possible.

Severity

WARNING

AN-1005

Message

, [AN-1005], ,, WARNING, , Slot

number>, port has bottleneck

cleared.

Probable Cause

Indicates that the bottleneck was cleared on the port.

Recommended

Action

No action is required.

Severity

WARNING

AN-1010

Message

, [AN-1010], ,, WARNING, , Severe

latency bottleneck detected at Slot port

number>.

Probable Cause

Indicates a credit loss.

Recommended

Action

Contact your vendor's customer support for assistance.

Severity

WARNING