Fabric OS Message Reference

307

53-1001767-01

FW-1167

42

FW-1167

Message

, [FW-1167], ,, INFO, , ,

Current value is .

Probable Cause

Indicates that the number of synchronization losses that the port experiences has changed from a
value outside of the acceptable range to a value within the acceptable range. Loss of
synchronization errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable.
Signal losses often create synchronization losses.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1168

Message

, [FW-1168], ,, INFO, , ,

.

Probable Cause

Indicates that the number of signal losses that the port experiences has changed. Loss of signal
generally indicates a physical problem.

Recommended

Action

Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.

Severity

INFO

FW-1169

Message

, [FW-1169], ,, INFO, , ,

is .

Probable Cause

Indicates that the number of signal losses that the port experiences has fallen below the low
boundary. Loss of signal generally indicates a physical problem.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. A low number of signal loss errors means that the switch is functioning
normally.

Severity

INFO

FW-1170

Message

, [FW-1170], ,, WARNING, , ,

is .