Message
Current value is
Probable Cause
Indicates that the number of synchronization losses that the port experiences has changed from a
value outside of the acceptable range to a value within the acceptable range. Loss of
synchronization errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable.
Signal losses often create synchronization losses.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1168
Message
Probable Cause
Indicates that the number of signal losses that the port experiences has changed. Loss of signal
generally indicates a physical problem.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.
Severity
INFO
FW-1169
Message
is
Probable Cause
Indicates that the number of signal losses that the port experiences has fallen below the low
boundary. Loss of signal generally indicates a physical problem.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. A low number of signal loss errors means that the switch is functioning
normally.
Severity
INFO
FW-1170
Message
is