HIL-1508
45
Severity
CRITICAL
HIL-1508
Message
faulty warning time expired. System preparing for shutdown.
Probable Cause
Indicates that temperatures in the system have remained above the critical threshold too long.
Recommended
Action
To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
CRITICAL
HIL-1509
Message
temperature (
shutdown.
Probable Cause
Indicates that temperatures in the system have risen above the critical threshold.
Recommended
Action
To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
CRITICAL
HIL-1510
Message
temperature (
shutdown cancelled.
Probable Cause
Indicates that temperatures in the system have dropped below the critical threshold; the system
can continue operation.
Recommended
Action
To help prevent future problems, make sure that all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
WARNING