Hil-1202, Hil-1203, Hil-1204 – Dell POWEREDGE M1000E User Manual
Page 448

372
Fabric OS Message Reference
53-1001767-01
HIL-1202
45
If the fan continues to generate this message, replace the fan FRU.
Severity
WARNING
HIL-1202
Message
number> faulted, speed ( Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. Recommended Action Replace the fan field-replaceable unit (FRU). Severity ERROR HIL-1203 Message number> faulted, speed ( Probable Cause Indicates that the specified fan speed (in RPMs) has risen above the maximum threshold. A high Recommended Action Run the tempShow command to verify that the switch temperatures are within operational ranges. Make sure that the area is well-ventilated and that the room temperature is within operational Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to generate this message, replace the fan FRU. Severity ERROR HIL-1204 Message number> faulted, speed ( Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This Recommended Action For the Brocade 3900 replace the fan FRU. For the Brocade 3016, 3250 and 3850, the entire switch must be replaced because these Severity ERROR
speed does not necessarily mean that the fan is faulty.
Refer to the hardware reference manual for the temperature range of your switch.
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
switches do not have field-replaceable units (FRUs).