Bl-1027, Bl-1028, Bl-1029 – Dell POWEREDGE M1000E User Manual
Page 144

68
Fabric OS Message Reference
53-1001767-01
BL-1027
7
Probable Cause
Indicates that an internal port went offline during the warm recovery of the switch. The switch will
reboot and start a cold recovery.
Recommended
Action
Collect supportSave information, then restart the switch and run the diagPost command to ensure
Power-On Self-Test (POST) is enabled. If the problem persists, replace the switch.
Severity
CRITICAL
BL-1027
Message
slot
status> 0x<1250 1 boot status>.
Probable Cause
Indicates that the blade failed to boot properly.
Recommended
Action
Restart or power cycle the blade.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1028
Message
faulted; internal processor was reset before switch init completed.
Probable Cause
Indicates that the switch's internal processor was reset before the initialization completed.
Recommended
Action
Restart or power cycle the switch.
If the message persists, replace the switch.
Severity
CRITICAL
BL-1029
Message
switch will be reset as part of the firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the datapath elements were
reset.
Recommended
Action
No action is required.
Severity
INFO