Zone-1013, Zone-1014, Zone-1015 – Dell POWEREDGE M1000E User Manual
Page 736: Zone-1017

660
Fabric OS Message Reference
53-1001767-01
ZONE-1013
111
Recommended
Action
Check the device connetion.
Severity
WARNING
ZONE-1013
Message
not supported.
Probable Cause
Indicates the QuickLoop feature is not supported in the current code release. If the QuickLoop
zoning configuration is enabled on the switch, it will not be supported.
Recommended
Action
Edit the zone database to remove the QuickLoop zoning definition in the effective configuration.
Severity
WARNING
ZONE-1014
Message
required license -
Probable Cause
Indicates the required zoning license is missing.
Recommended
Action
Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a
zoning license if you do not have one.
Severity
ERROR
ZONE-1015
Message
of the current transaction
Probable Cause
Indicates that a zoning change operation is not allowed because the zoning transaction is opened
by another task. Indicates concurrent modification of the zone database by multiple administers.
Recommended
Action
Wait until the previous transaction is completed. Verify that only one administrator is working with
the zone database at a time.
Severity
WARNING
ZONE-1017
Message
name>) contains incorrect number of Initiator and Target devices.