Swch-1015, Swch-1016, Swch-1017 – Dell POWEREDGE M1000E User Manual
Page 703

Fabric OS Message Reference
627
53-1001767-01
SWCH-1015
98
Recommended
Action
No action is required.
Severity
INFO
SWCH-1015
Message
name> Probable Cause Indicates that an internal problem has been detected by the software. This is usually an internal Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING SWCH-1016 Message name of device>fdiscs to port requested not assigned to the device. Reject FDISC. Probable Cause Indicates static persistent PID is set and the area requested is not assigned to the device. Recommended Action This is a NPIV device and static peristent PID is set on it, we are not able to assign the area Severity INFO SWCH-1017 Message name of device> tries to flogi to port PID is set on the Loop device. Probable Cause Indicates persistent PID is set and static Persistent PID is not supported on the Loop device. Recommended Action This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove Severity INFO
Fabric OS problem or due to file corruption.
requested. Remove the static binding to have the device come up with a different area and run the
wwnaddress --unbind wwn command.
the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn
command.