Fabric OS Message Reference

627

53-1001767-01

SWCH-1015

98

Recommended

Action

No action is required.

Severity

INFO

SWCH-1015

Message

, [SWCH-1015], ,, WARNING, ,

name> .

Probable Cause

Indicates that an internal problem has been detected by the software. This is usually an internal
Fabric OS problem or due to file corruption.

Recommended

Action

Restart or power cycle the switch

If the message persists, run the firmwareDownload command to update the firmware.

Severity

WARNING

SWCH-1016

Message

, [SWCH-1016], ,, INFO, , Device

name of device>fdiscs to port . Static persistent PID set and area

requested not assigned to the device. Reject FDISC.

Probable Cause

Indicates static persistent PID is set and the area requested is not assigned to the device.

Recommended

Action

This is a NPIV device and static peristent PID is set on it, we are not able to assign the area
requested. Remove the static binding to have the device come up with a different area and run the
wwnaddress --unbind wwn command.

Severity

INFO

SWCH-1017

Message

, [SWCH-1017], ,, INFO, , Device

name of device> tries to flogi to port , reject FLOGI as persistent

PID is set on the Loop device.

Probable Cause

Indicates persistent PID is set and static Persistent PID is not supported on the Loop device.

Recommended

Action

This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove
the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn
command.

Severity

INFO