Conf-1030, Conf-1031, Conf-1032 – Dell POWEREDGE M1000E User Manual
Page 195: Conf-1040

Fabric OS Message Reference
119
53-1001767-01
CONF-1030
17
CONF-1030
Message
Configuration database full, data not committed (key:
data>.
Probable Cause
Indicates that the previous configuration commands have resulted in a database full condition.
Configuration changes associated with the specified key have not been applied.
Recommended
Action
Use the configure command and various other commands to erase configuration parameters that
are no longer required. As a last resort, execute the configDefault command and reconfigure the
system.
Severity
WARNING
CONF-1031
Message
completed successfully.
Probable Cause
Indicates that the configDefault command was initiated and completed successfully.
Recommended
Action
No action is required.
Severity
INFO
CONF-1032
Message
completed successfully.
Probable Cause
Indicates that the configRemove command was initiated and completed successfully.
Recommended
Action
No action is required.
Severity
INFO
CONF-1040
Message
failed.
Probable Cause
Indicates a configDefault error has occurred.
Recommended
Action
Correct the error and try again.
Severity
INFO