Conf-1030, Conf-1031, Conf-1032 – Dell POWEREDGE M1000E User Manual
Page 195: Conf-1040

Fabric OS Message Reference
119
53-1001767-01
CONF-1030
17
CONF-1030
Message
Configuration database full, data not committed (key: data>. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition. Recommended Action Use the configure command and various other commands to erase configuration parameters that Severity WARNING CONF-1031 Message completed successfully. Probable Cause Indicates that the configDefault command was initiated and completed successfully. Recommended Action No action is required. Severity INFO CONF-1032 Message completed successfully. Probable Cause Indicates that the configRemove command was initiated and completed successfully. Recommended Action No action is required. Severity INFO CONF-1040 Message failed. Probable Cause Indicates a configDefault error has occurred. Recommended Action Correct the error and try again. Severity INFO
Configuration changes associated with the specified key have not been applied.
are no longer required. As a last resort, execute the configDefault command and reconfigure the
system.