Ips-1005, Ips-1006 – Dell POWEREDGE M1000E User Manual
Page 480

404
Fabric OS Message Reference
53-1001767-01
IPS-1005
54
Probable Cause
Indicates that configured Port Mode is different from the intended use.
Recommended
Action
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the
port mode to neutral before attempting to configure the port for a different mode or use.
Severity
WARNING
IPS-1005
Message
Authorization Failure for slot (
reason (
Probable Cause
Indicates that tunnel setup failed because of an authorization failure from the remote side. A
reason for such a failure could be a WWN mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up
the tunnel.
Severity
WARNING
IPS-1006
Message
Configuration Mismatch for slot (
reason (
Probable Cause
Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason for such a mismatch could be a Compression setting or WanTOV enforcement.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to match that of the other side to set up
the tunnel.
Severity
WARNING