Fw-1274, Fw-1275, Fw-1296 – Dell POWEREDGE M1000E User Manual
Page 398

322
Fabric OS Message Reference
53-1001767-01
FW-1274
42
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1274
Message
above high boundary(High=
Probable Cause
Indicates that the number of frame types or commands that the port receives has risen above the
high boundary. The port has received a small computer system interface (SCSI) Read, SCSI Write,
SCSI Read and Write, SCSI Traffic, or IP commands in a frame.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1275
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the number of frame types or commands that the port receives has changed from a
value outside of the acceptable range to a value within the acceptable range. The port has received
a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP
commands in a frame.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1296
Message
has changed(High=
Probable Cause
Indicates that the number of Telnet violations has changed. Telnet violations indicate that a Telnet
connection request has been received from an unauthorized IP address. The TELNET_POLICY
contains a list of internet protocol (IP) addresses that are authorized to establish Telnet
connections to switches in the fabric.
Recommended
Action
Run the errShow command to determine the IP address that sent the request. Responses to
security-class messages depend on user policies. Consult your security administrator for response
strategies and policies.