Trce-1007, Trce-1008, Trce-1009 – Dell POWEREDGE M1000E User Manual
Page 713: Trce-1010

Fabric OS Message Reference
637
53-1001767-01
TRCE-1007
102
TRCE-1007
Message
of this CP has failed. Parameters temporarily out of sync with other CP.
Probable Cause
Indicates that the active CP is unable to alert the standby CP of a change in trace status. This
message is only applicable to the Brocade 24000, and 48000.
Recommended
Action
This message is often transitory. Wait for a few minutes and retry the command.
If the message persists, run the supportFtp command to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity
ERROR
TRCE-1008
Message
Unable to load trace parameters.
Probable Cause
Indicates that the active CP is unable to read stored trace parameters.
Recommended
Action
Restart the CP (dual-CP system) or restart the switch.
If the message persists, run the supportFtp command to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity
CRITICAL
TRCE-1009
Message
alert active CP that a dump has occurred.
Probable Cause
Indicates that the standby CP is unable to communicate trace information to active CP. This
message is only applicable to the Brocade 24000 and 48000.
Recommended
Action
Run the haShow command to verify that the current CP is standby and the active CP is active.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
TRCE-1010
Message
to start