Sysc system messages, Chapter 99, Sysc-1001 – Dell POWEREDGE M1000E User Manual
Page 705: Sysc-1002, Sysc-1003, Chapter

Fabric OS Message Reference
629
53-1001767-01
Chapter
99
SYSC System Messages
SYSC-1001
Message
Failed to run error message (string)>. Probable Cause Indicates that during the boot sequence, one of the programs does not run on the system. Recommended Action If the message is reported during a restart after new firmware has been loaded, try reloading the If the message persists, there might be a conflict between the two versions of firmware or the Severity CRITICAL SYSC-1002 Message Switch bring-up timed out. Probable Cause Indicates the system has timed out during a restart or failover sequence, waiting for one or more Recommended Action The switch is in an inconsistent state and can be corrected only by a restart or power cycle. Before Severity CRITICAL SYSC-1003 Message Chassis config option is not supported by CP Blade with ID CP>. Change the chassis configuration Probable Cause Indicates that on system startup, the option configuration file corresponding to the chassisConfig
firmware using the firmwareDownload command.
nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP
transfers and run the supportSave command then contact your switch service provider.
programs to register with system services or to fail over to active status.
restarting the chassis, record the firmware version on the switch or control processor (CP) and run
the haDump command. If this is a dual-CP switch, then gather the output from the CP in which this
log message appeared.
option read could not be found. This indicates that option is not supported on this platform running
this version of the firmware.