Fw-1039, Fw-1040, Fw-1041 – Dell POWEREDGE M1000E User Manual
Page 367

Fabric OS Message Reference
291
53-1001767-01
FW-1039
42
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the
low boundary. The receive performance area measures the amount of incoming laser to help you
determine if the SFP is in good working condition or not. If the counter often exceeds the threshold,
the SFP is deteriorating.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables
or SFPs. Check for damage from heat or age.
Severity
WARNING
FW-1039
Message
above high boundary(High=
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has risen above the
high boundary. The receive performance area measures the amount of incoming laser to help you
determine if the SFP is in good working condition or not. If the counter often exceeds the threshold,
the SFP is deteriorating.
Recommended
Action
Replace the SFP before it deteriorates.
Severity
WARNING
FW-1040
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has changed from a
value outside of the acceptable range to a value within the acceptable range. The receive
performance area measures the amount of incoming laser to help you determine if the SFP is in
good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1041
Message
has changed(High=