Hamk system messages, Chapter 44, Hamk-1001 – Dell POWEREDGE M1000E User Manual
Page 443: Hamk-1002, Hamk-1003, Chapter

Fabric OS Message Reference
367
53-1001767-01
Chapter
44
HAMK System Messages
HAMK-1001
Message
CRITICAL,
Probable Cause
Indicates the switch failed during the warm recovery.
Recommended
Action
This message triggers a switch reboot automatically and attempts a cold recovery. Run the
supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
CRITICAL
HAMK-1002
Message
Probable Cause
Indicates that the active control processor (CP) blade determined that the standby CP blade is
down. This can be a result of an operator-initiated action such as the firmwareDownload command,
the standby CP blade being reset or removed, of an error in the standby CP blade.
Recommended
Action
Monitor the standby CP blade for a few minutes. If this message is due to a standby CP reboot, the
message HAMK-1003 will display after the standby CP has completed the reboot successfully.
If the standby CP does not successfully connect to the active CP after 10 minutes, reboot the
standby CP blade by ejecting the blade and reseating it.
Severity
INFO
HAMK-1003
Message
Probable Cause
Indicates that the active control processor (CP) blade detects the standby CP blade. This message
indicates that the standby CP blade is available to take over in case a failure happens on the active
CP blade.
Recommended
Action
No action is required. This message means that the standby CP is healthy.
Severity
INFO