Auth-1004, Auth-1005, Auth-1006 – Dell POWEREDGE M1000E User Manual
Page 116: Auth-1007

40
Fabric OS Message Reference
53-1001767-01
AUTH-1004
4
AUTH-1004
Message
type to
Probable Cause
Indicates that the authUtil command has failed to set the authentication configuration value. The
data type is either authentication type, DH group type, or policy type.
Recommended
Action
Retry the authUtil command.
Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1005
Message
Authentication file does not exist:
.
Probable Cause
Indicates an authentication file corruption.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1006
Message
open authentication configuration file.
Probable Cause
Indicates an internal problem with the Secure Fabric OS.
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING
AUTH-1007
Message
authentication protocols are not supported: port
.
Probable Cause
Indicates that the proposed authentication protocol type or types are not supported by the local
specified port.