Fabric OS Message Reference

53-1001767-01

AUTH-1004

4

AUTH-1004

Message

, [AUTH-1004], ,, ERROR, , Failed to set

type to .

Probable Cause

Indicates that the authUtil command has failed to set the authentication configuration value. The
data type is either authentication type, DH group type, or policy type.

Recommended

Action

Retry the authUtil command.

Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

ERROR

AUTH-1005

Message

, [AUTH-1005], ,, ERROR, ,

Authentication file does not exist:

.

Probable Cause

Indicates an authentication file corruption.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

ERROR

AUTH-1006

Message

, [AUTH-1006], ,, WARNING, , Failed to

open authentication configuration file.

Probable Cause

Indicates an internal problem with the Secure Fabric OS.

Recommended

Action

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

AUTH-1007

Message

, [AUTH-1007], ,, ERROR, , The proposed

authentication protocols are not supported: port

.

Probable Cause

Indicates that the proposed authentication protocol type or types are not supported by the local
specified port.