Fabric OS Message Reference
625
53-1001767-01
SWCH-1008
98
Recommended
Action
Based on the disable reason displayed, proper corrective action may to be required to restore the
port.
If the disable reason is due to insufficient frame buffers, reduce the distance or speed settings for
the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port
group must be disabled to make more buffers available for the link.
Refer to the Fabric OS Administrator’s Guide for more information about buffers.
Severity
WARNING
SWCH-1008
Message
string> are port swapped on ports that do not support port swap. Slot number> will be faulted. Probable Cause Indicates the blade is enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default Refer to the Fabric OS Administrator’s Guide for more information on port swapping. Severity WARNING SWCH-1009 Message having Trunk Area (TA) enabled on slot enabled will be persistenly disabled. Probable Cause Indicates the blade is enabled with a port configuration that had Trunk Area previously enabled on Recommended Action You must disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS Administrator’s Guide for more information. Severity WARNING SWCH-1010 Message (TA) enabled on slot ports will be persistently disabled. Probable Cause Indicates the blade is enabled with the port configuration that had Trunk Area enabled previously. Recommended Action You must disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS Administrator’s Guide for more information.
area.